Inspection
- Turn the ignition off.
- Disconnect the intake actuator connector.
- Make sure the intake actuator moves to the fresh air position when 12 V is applied to terminal 4 and terminal 3 is grounded. Make sure the intake actuator moves to the recirculation position when the connections are reversed.

1. -
2. -
3. Fresh
4. Sensor (+5V)5. Feedback signal
6. Sensor ground
7. Recirculation - Connect the intake actuator connector.
- Turn the ignition on.
- Check the voltage between terminals 6 and 5. Specification
Door Position Voltage (V) Fresh 0,3 Recirculation 4.7 - If the intake actuator does not operate properly, replace it with a known good intake actuator and check operation.
- If the problem is resolved, replace the intake actuator.
Replacement
- Disconnect the negative (-) battery terminal.
- Remove the driver airbag module assembly. (Refer to Body - "Driver Airbag Module Assembly")
- Disconnect the connector, then remove the intake door actuator (A) after loosening the mounting screws.

- Install in the reverse order of removal.