SYMPTOM

Compressor does not operate.

Diagnosis Procedure

CHECK MAGNET CLUTCH OPERATION

Check magnet clutch. Refer to Diagnosis Procedure.

Does it operate normally?

YES>>

GO TO 2.

NO>>

Repair or replace malfunctioning parts.

CHECK REFRIGERANT PRESSURE SENSOR

Check refrigerant pressure sensor. Refer to Diagnosis Procedure.

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace malfunctioning parts.

CHECK A/C AUTO AMP. OUTPUT SIGNAL

With CONSULT

  1. Select “Data Monitor” mode of “HVAC” using CONSULT.

  2. Select “COMP REQ SIG” and “FAN REQ SIG”, and check status under the following conditions.

Monitor itemConditionStatus
COMP REQ SIG A/C switch OFF Off
ON On
FAN REQ SIG Front blower motor OFF Off
ON On

Is the inspection result normal?

YES>>

Replace IPDM E/R. Refer to Removal and Installation.

NO>>