Compressor dose dot operate
Description
SYMPTOM
Compressor dose not operate.
Diagnosis Procedure
NOTE:• Perform self-diagnoses with CONSULT-III before performing symptom diagnosis. If any DTC is detected, perform the corresponding diagnosis.
• Check that refrigerant is enclosed in cooler cycle normally. If refrigerant amount is shortage from proper amount, perform the inspection of refrigerant leakage.
1.CHECK MAGNET CLUTCH OPERATIONCheck magnet clutch. Refer to HAC-83, "Component Function Check".
Does it operate normally? YES >> GO TO 2.
NO >> Repair or replace malfunctioning parts.
2.CHECK REFRIGERANT PRESSURE SENSORCheck refrigerant pressure sensor. Refer to EC-423, "Component Function Check".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace malfunctioning parts.
3.CHECK A/C ON SIGNALCheck A/C ON signal. Refer to HAC-75, "Component Function Check".
Is inspection result normal? YES >> GO TO 4.
NO >> Repair or replace malfunctioning parts.
4.CHECK BLOWER FAN ON SIGNALCheck blower fan ON signal. Refer to HAC-77, "Component Function Check".
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair or replace malfunctioning parts 5.CHECK BCM OUTPUT SIGNAL
With CONSULT-III
1. Select “DATA MONITOR” mode of “ECM” using CONSULT-III.
2. Select “AIR COND SIG” and “HEATER FAN SW”, and check status under the following conditions.

Is the inspection result normal? YES >> Replace IPDM E/R. Refer to PCS-34, "Removal and Installation" (with Intelligent Key) or PCS-63, "Removal and Installation" (without Intelligent Key).
NO >> Replace BCM. Refer to BCS-93, "Removal and Installation" (with Intelligent Key) or BCS-161, "Removal and Installation" (without Intelligent Key).