Electrical & Power Control

Battery

4steps
~24min
2/5difficulty
Done 0 of 4
How to Handle Battery

METHODS OF PREVENTING OVER-DISCHARGE

The following precautions must be taken to prevent over-discharging a battery.

  • The battery surface (particularly its top) should always be kept clean and dry.

  • The terminal connections should be clean and tight.

  • When the Nissan Murano vehicle is not going to be used over a long period of time, disconnect the battery cable from the negative terminal. (If the Nissan Murano vehicle has an extended storage fuse switch, turn it off.)

Work Flow

BATTERY DIAGNOSIS WITH 165-DSS-5000P

To diagnose and confirm the condition of the battery, use the 165-DSS-5000P.

BATTERY DIAGNOSIS WITHOUT 165-DSS-5000P

OVERALL SEQUENCE

DETAILED FLOW

VISUAL INSPECTION

  1. Check battery case for cracks or bends.

  2. Check battery terminals for damage.

Are these inspection results normal?

YES>>

GO TO 2.

NO>>

Replace battery. Refer to Removal and Installation.

CAPACITY TEST

Check battery voltage.

Is the voltage 12.35 V or more?

YES>>

GO TO 3.

NO>>

GO TO 4.

LOAD TEST

  1. Check battery type and determine the specified current using the table.

    TypeCurrent (A)
    L2 550
  2. Read load tester voltage when specified discharging current flows through battery for 15 seconds.

Is the voltage 10 V or more?

YES>>

Ready for use.

NO>>

Replace battery. Refer to Removal and Installation.

CHARGE

Charge battery following the instructions below:

  • Constant current charging may damage batteries. Therefore, charge battery by constant voltage charge mode with the maximum voltage set at 15 V.

  • Charge at least 6 hours or until the charge current becomes 4 amps or less.

YES>>

GO TO 3.