Main Power Window and Door Lock/unlock Switch
CHECK POWER SUPPLY
Ignition switch OFF.
Disconnect main power window and door lock/unlock switch connectors.
Ignition switch ON.
Check voltage between main power window and door lock/unlock switch harness connectors and ground.
(+) (–) Voltage
(Approx.)Main power window and door lock/unlock switch Connector Terminal D7 10 Ground Battery voltage D8 18
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK POWER SUPPLY CIRCUIT
Ignition switch OFF.
Disconnect BCM connector.
Check continuity between BCM harness connector and main power window and door lock/unlock switch harness connectors.
BCM Main power window and door lock/unlock switch Continuity Connector Terminal Connector Terminal M81 140 D7 10 Yes 141 D8 18 Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M81 140 No 141
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK GROUND CIRCUIT
Ignition switch OFF.
Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 1 Yes
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident.
>>Inspection End.