Body Exterior, Doors, Roof & Vehicle Security

Main Power Window and Door Lock/unlock Switch

10steps
~60min
3/5difficulty
Done 0 of 10
Diagnosis Procedure

CHECK POWER SUPPLY

  1. Ignition switch OFF.

  2. Disconnect main power window and door lock/unlock switch connectors.

  3. Ignition switch ON.

  4. Check voltage between main power window and door lock/unlock switch harness connectors and ground.

    (+)(–)

    Voltage

    (Approx.)
    Main power window and door lock/unlock switch
    ConnectorTerminal
    D7 10 Ground Battery voltage
    D8 18

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

GO TO 2.

CHECK POWER SUPPLY CIRCUIT

  1. Ignition switch OFF.

  2. Disconnect BCM connector.

  3. Check continuity between BCM harness connector and main power window and door lock/unlock switch harness connectors.

    BCMMain power window and door lock/unlock switchContinuity
    ConnectorTerminalConnectorTerminal
    M81 140 D7 10 Yes
    141 D8 18
  4. Check continuity between BCM harness connector and ground.

    BCM Ground Continuity
    Connector Terminal
    M81 140 No
    141

Is the inspection result normal?

YES>>

Replace BCM. Refer to Removal and Installation.

NO>>

Repair or replace harness.

CHECK GROUND CIRCUIT

  1. Ignition switch OFF.

  2. Check continuity between main power window and door lock/unlock switch harness connector and ground.

    Main power window and door lock/unlock switch Ground Continuity
    Connector Terminal
    D7 1 Yes

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Repair or replace harness.

CHECK INTERMITTENT INCIDENT

Refer to Intermittent Incident.

>>

Inspection End.