Component Function Check

COMBINATION METER INPUT SIGNAL

CONSULT

  1. Select “PKB SW” in “Data Monitor” mode of “METER/M&A”.

  2. Check that the function operates normally according to the following conditions:

Monitor item Condition Status
PKB SW When parking brake is applied ON
When parking brake is released OFF

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Refer to Diagnosis Procedure.

Diagnosis Procedure

CHECK PARKING BRAKE SWITCH CIRCUIT

  1. Disconnect combination meter harness connector and parking brake switch harness connector.

  2. Check continuity between combination meter harness connector and parking brake switch harness connector.

    Combination meter Parking brake switch Continuity
    Connector Terminal Connector Terminal
    M24 26 E52 1 Yes
  3. Check continuity between combination meter harness connector and ground.

    Combination meter Ground Continuity
    Connector Terminal
    M24 26 No

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Repair or replace harness or connector.

Component Inspection

CHECK PARKING BRAKE SWITCH

Check continuity between parking brake switch and switch case ground.

ComponentTerminalConditionContinuity
Parking brake switch 1 Parking brake applied Yes
Parking brake released No

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Replace parking brake switch. Refer to Removal and Installation.