Help
ADDITIONAL CHECKS
COMMAND MODES G--*
To use this function, enter G on the XR 25 tool keypad, then the number of the chosen command followed by an asterisk.
03 Interior light control (switches the interior light on for 3 seconds).
04 Forced protected mode: activates the immobilizer function even if the key is valid, allowing the engine start prohibition to be checked. The left bargraph 9 must light up.
This command must be entered with the ignition off while the immobilizer is active.
Warning: switching off the ignition cancels this command.
05 Immobilizer warning light command (turns on the immobilizer warning light for 3 seconds).
08 Door unlocking command (activates the unlocking-side micromotors for 3 seconds).
09 Door locking command (activates the locking-side micromotors for 3 seconds).
13 End of diagnosis.
22 Configuration:
G 22 * 1 * = petrol configuration (right bargraph 3 must be off).
G 22 * 2 * = diesel configuration (right bargraph 3 must be on).
23 Forced solenoid valve test mode (used on diesel vehicles only).
Activates the coded solenoid valve (opening/closing) for approximately 30 seconds (active control).
Note: - the decoder box must be configured for diesel
The left bargraph 8 must be on during the test.
32 Learning of second TIR key.
39 Transponder line.
ADDITIONAL CHECKS
COMMAND MODES G--*
40 Entry of fault code (left bargraph 10 must be on and ignition on).
This command mode can be used to enter the fault code, but does not allow decoding of the injection computer or coded solenoid valve.
Enter the vehicle's fault code number on the XR 25 tester keypad and confirm with the "*" key.
If the code number is correct, "OK" is displayed on the XR 25 tester display and the left bargraph 10 turns off.
If the code number is incorrect, "End" is displayed on the XR 25 tester display and the left bargraph 10 remains on.
WARNING: you have 3 attempts to enter the code. If the code is invalid after the 3rd attempt, wait approximately 15 minutes before trying again (between each code attempt, the ignition must be switched off and back on).
47 Interior lamp delay configuration:
G 47 * 0 * = interior lamp delay cancelled.
G 47 * 1 * = interior lamp delay activated.
70 Reading of MPR number (decoder box reference).
LIST OF VARIOUS #
43 CPE button type.
26 Source of last opening command:
→ Infrared remote control
→ Central door locking button
27 Reading of direction of last opening command:
→ Unlocking
→ Locking
65 E2 Prom test.
95 Manufacturer (1 = Valeo, 2 = Sagem).
CLIP REMOVAL AND REFITTING
To remove the clips and tabs of the wiring of the two decoder box connectors, you must use an Elé. 1263 tool set. Not using this tool could irreparably damage the connector and the wiring.
Use the black tool to unclip the modules.
Use the brown tool to remove the clips.

Test yourself
A quick Renault Kangoo quiz: every answer comes with an explanation and a link to the manual page.