Installation
INSTALLATION
PRECAUTION / NOTICE / HINT
NOTICE:
- Avoid any impact to the blind spot monitor sensor.
- Do not drop the left blind spot monitor sensor. If the sensor is dropped, replace it with a new one.
HINT:
- The blind spot monitor beam axis check is performed to verify whether the sensor transmits radio waves.
- The blind spot monitor beam axis confirmation is performed to verify whether the sensor beam axis is correct, and to adjust the beam axis using the reflector.
- The blind spot monitor sensor installation condition check is performed to verify, using a gauge, whether the sensor is perpendicular to the ground (+/-5°), and whether the sensor is 16 to 24° from the line parallel to the vehicle centerline.
PROCEDURE
1. INSTALL LEFT BLIND SPOT MONITOR BRACKET
(a) Install the left blind spot monitor sensor bracket using the 3 nuts.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
2. INSTALL RIGHT BLIND SPOT MONITOR BRACKET
HINT:
Perform the same procedure as for the left side.
3. INSTALL LEFT BLIND SPOT MONITOR SENSOR
(a) Connect the connector.
(b) Install the left blind spot monitor using the 3 nuts.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
4. INSTALL RIGHT BLIND SPOT MONITOR SENSOR
HINT:
Perform the same procedure as for the left side.
5. PERFORM BLIND SPOT MONITOR SENSOR INSTALLATION CONDITION CHECK
Click here![]()
6. INSTALL REAR BUMPER ASSY
Click here![]()
7. CONFIRM BLIND SPOT MONITOR BEAM AXIS
Click here![]()
SST: 09870-60000
09870-60010
SST: 09870-60040
8. PERFORM DIAGNOSTIC SYSTEM CHECK
Click here![]()