Engine, Hybrid System

Inspection

~1min read

INSPECTION

PROCEDURE

1. INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

(a) Measure the resistance according to the value(s) in the table below.

HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.

Standard Resistance:

Tester Connection

ATF Temperature

Specified Condition

2 (OT-) - 13 (OT+)

10 °C

5 to 8 kΩ

2 (OT-) - 13 (OT+)

25 °C

2.5 to 4.5 kΩ

2 (OT-) - 13 (OT+)

110 °C

0.22 to 0.28 kΩ

3 (OT2-) - 14 (OT2+)

10 °C

5 to 8 kΩ

3 (OT2-) - 14 (OT2+)

25 °C

2.5 to 4.5 kΩ

3 (OT2-) - 14 (OT2+)

110 °C

0.22 to 0.28 kΩ

If the result is not as specified, replace the transmission wire.