INSPECTION
PROCEDURE
1. INSPECT AIR SWITCHING VALVE ASSEMBLY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
1 - 5 |
20 °C |
4.5 to 5.5 Ω |
1 - Body ground |
Always |
1 MΩ or higher |
5 - Body ground |
Text in Illustration
*a |
Component without harness connected
(Air Switching Valve Assembly) |
NOTICE:
When measuring the resistance, do not touch terminals 2, 3 or 4.
HINT:
When measuring the resistance, make sure that the surface temperature of the air switching valve assembly is 20 °C.
If the result is not as specified, replace the air switching valve assembly. |
 |
(b) Check the operation of the air switching valve assembly.
(1) Check that air does not flow from port A to port B. Text in Illustration
*a |
Port A |
*b |
Port B |
 |
Air |
NOTICE:
Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.
If the result is not as specified, replace the air switching valve assembly.
(2) Apply battery voltage across terminals 1 and 5. Text in Illustration
*a |
Component without harness connected
(Air Switching Valve Assembly) |
*b |
Port A |
*c |
Port B |
 |
Air |
NOTICE:
When applying voltage, do not touch terminals 2, 3 or 4.
(3) Check that air flows from port A to port B.
If the result is not as specified, replace the air switching valve assembly. |