Electrical system, general information

Charging battery with battery charger -VAS 5095 A-

~1min read
WARNING

Danger of injury! Observe warning notices and safety regulations → Chapter!

Special tools and workshop equipment required

Battery charger -VAS 5095 A-

Caution Always set battery type 2.4 V/C (volts/battery cell) when charging! This applies for all batteries.
Note

The battery must have a temperature of at least 10 °C.

WARNING It is not permissible to test or charge batteries whose magic eye shows light yellow. Do not slave/jump start the vehicle!

Danger of explosion when checking and charging or slave/jump starting.

These batteries must be renewed.

  • Switch off ignition and all electrical consumers.
  • Check setting for battery type on type of battery switch → Chapter. Must be set to 2.4 V/C (volts/battery cell).
  • Connect red terminal clamp “+” of charger unit to positive terminal on battery.
Note In vehicles with start/stop function and battery monitor control unit -J367- fitted, black terminal clamp “-” must be connected to body earth. Connecting it to battery negative terminal will cause start/stop system to malfunction.
  • Connect black terminal clamp “-” of battery charger to negative terminal.
  • Switch on battery charger → Chapter.
The charge current indicators → Fig.-2- and -3- light up yellow. When only the light emitting diode (LED) -3- lights up yellow, battery is partially discharged (approx. 90%). If the LED lights up green → Fig.-4- the charger has switched to "maintaining charge". The battery is fully charged.
  • Switch off charging unit → Chapter.
  • Remove charger unit terminals from battery terminals.
Charging battery with battery charger -VAS 5095 A-