Electrical System General Information

Lights, lamps, switches - exterior

~3min read

Application and safety notes for gas discharge lamps

- If assembly work is carried out on the headlamp with gas discharge lamps, observe the following:

  • Warnings of dangerous high voltage / currents
  • Warnings of pressure, temperature and radiation / electric arc
  • Installation notes for gas discharge lamps
  • Disposal regulations for gas discharge lamps

Required special tools, testers and equipment, and auxiliary items

  • Safety goggles
  • Gloves


WARNING!

Before working on parts of the headlamp with gas discharge lamp that are marked with yellow high-voltage symbols, be sure to disconnect the battery negative lead.

Then switch the low beam on and off again. This discharges any residual voltage.

The gas discharge lamp control unit must never be operated without a gas discharge lamp.

Due to the high voltages (over 28000 V when the gas discharge lamp ignites) and temperatures, the gas discharge lamp may only be operated inside the headlamp housing.


WARNING!

Never replace lamps unless you are familiar with the relevant procedures, safety precautions and tools.

Warnings of dangerous high voltage / currents


WARNING!

Light system control units, connectors or components in the area of the lamp socket carry dangerous high voltage that can be fatal.

Operating the control unit and ignition unit is only permitted with the lamp fitted.


WARNING!

  • Switch off the ignition and all electrical consumers and remove the ignition key.
  • When working on the headlamp system, make sure that all components are de-energised, including discharging residual voltage after the headlamps have been switched off.
  • Residual voltage is discharged by switching the low beam on and off after removing the ignition key.
  • When working on the headlamp system, make sure that the lights cannot be switched on.

Warnings of pressure, temperature and radiation / glare


WARNING!

  • The lamp may only be operated inside the headlamp housing (protection against contact due to the very hot lamp, absorption of UV radiation, avoiding glare hazard, explosion protection).
  • Bulb glass envelopes can become very hot - risk of burns!
  • Do not look directly into the light beam, as the UV radiation of the gas discharge lamp is approx. 2.5 times higher than with conventional halogen light.
  • Do not look into the light beam (risk of glare); vision may be impaired for an extended period.


WARNING!

  • Avoid contact with a cracked bulb glass envelope.
  • H 7 - Bulbs and gas discharge lamps (Xenon / Bi-Xenon) are under pressure and may burst when replacing the bulb - risk of injury!
  • When removing and installing the gas discharge lamp, always wear safety goggles and gloves.

Installation notes for gas discharge lamps


Caution!

  • Always switch off the relevant consumer before replacing a bulb.
  • Switch off the ignition and all electrical consumers and remove the ignition key.
  • Do not touch the glass envelope of the bulb with bare fingers; use clean cloth gloves. A fingerprint left behind would evaporate due to the heat of the switched-on bulb and deposit on the reflector, impairing the headlamp's light output.
  • A bulb may only be replaced by a bulb of the same type. The designation is marked on the lamp base or on the glass envelope.
  • When installing, make sure connectors engage correctly and are firmly seated.

Disposal regulations for gas discharge lamps


WARNING!

  • Gas discharge lamps must be disposed of as special waste; never dispose of gas discharge lamps with household waste.
  • Gas discharge lamps contain metallic mercury (Hg) and traces of thallium; they must not be destroyed.
  • These components must be recycled properly in accordance with national legislation.
  • Dispose of only in designated containers at the responsible collection point.