Electrical
Specifications
In this manual: Electrical
~3min read
General Specifications
| Item | Specification |
|---|---|
| 2.3 L EcoBoost - Limited and XLT with trailer packages built before October 2020 | |
| Rating | 220 amp |
| Generator Output at 80.6°F (27°C) | from 117.9 A at 700 rpm (min.) to 231.1 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,44 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 2.3 L EcoBoost - Base, XLT and Timberline vehicles built after October 2020 | |
| Rating | 150 amps |
| Generator Output at 80.6°F (27°C) | from 94.7 A at 750 rpm (min.) to 134.7 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,76 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 2.3 L EcoBoost - Limited vehicles built after June 2021 | |
| Rating | 200 amp |
| Generator Output at 80.6°F (27°C) | from 108.5 A at 700 rpm (min.) to 219.3 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,44 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 3 L EcoBoost - all vehicles except police built before October 2020 | |
| Rating | 220 amp |
| Generator Output at 80.6°F (27°C) | from 112.6 A at 625 rpm (min.) to 233.7 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,69 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 3 L EcoBoost - all ST vehicles built after October 2020 | |
| Rating | 220 amp |
| Generator Output at 80.6°F (27°C) | from 112.6 A at 625 rpm (min.) to 233.7 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,69 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 3 L EcoBoost - King Ranch. Platinum vehicles built after June 2021 | |
| Rating | 200 amp |
| Generator Output at 80.6°F (27°C) | from 95.1 A at 625 rpm (min.) to 184 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,69 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 3 L EcoBoost - Police vehicles | |
| Rating | 250 amp |
| Generator Output at 80.6°F (27°C) | from 103.3 A at 625 rpm (min.) to 226.5 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,69 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 3.3 L Duratec - all except police vehicles | |
| Rating | 200 amp |
| Generator Output at 80.6°F (27°C) | from 95.1 A at 625 rpm (min.) to 184 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,67 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |
| 3.3 L Duratec - Police vehicles | |
| Rating | 250 amp |
| Generator Output at 80.6°F (27°C) | from 106.5 A at 625 rpm (min.) to 199 A at 2500 rpm (max.) |
| Generator Pulley Ratio | 2,67 |
| Generator Pulley Replaceable | Yes |
| Generator Pulley Type | Generator Decoupler with Overrunning Alternator Decoupler (OAD) |
| Voltage Regulator Type | Electronic Internal with Generator |