Electrical System

Charging Condition Inspection

~1min read

Battery charging condition can be checked by measuring battery terminal voltage with a digital voltmeter [A].

  • Remove the seat (see Seat Removal in the Frame chapter).
  • Disconnect the battery terminals.
Charging Condition Inspection

NOTICE

Be sure to disconnect the negative (–) cable first.

  • Measure the battery terminal voltage.

NOTE

Measure with a digital voltmeter which can be read one decimal place voltage.

If the reading is 12.8 V or more, refresh charge is not required, however, if the read is below the 12.8 V, refresh charge is required.

Battery Terminal Voltage Standard: 12.8 V or more

Terminal Voltage (V) [A] Battery Charge Rate (%) [B] Good [C] Refresh charge is required [D]

Charging Condition Inspection