Self-Diagnosis System

Subthrottle Valve Actuator Resistance Inspection

~1min read
  • Turn the ignition switch to OFF.
  • Disconnect the subthrottle valve actuator connector [A].
Subthrottle Valve Actuator Resistance Inspection

  • Connect a digital meter to the subthrottle valve actuator connector [A].
  • Measure the subthrottle valve actuator resistance.

Subthrottle Valve Actuator Resistance Connections: Y/BK lead [1] ←→ P/BL lead [2] G lead [3] ←→ BK/O lead [4] Standard: About 6.3 9.5 Ω


Subthrottle Valve Actuator Resistance Inspection

If the reading is out of the standard, replace the throttle body assy.

If the reading is within the standard, check the input voltage (see Subthrottle Valve Actuator Input Voltage Inspection).

Test yourself

A quick Kawasaki Ninja ZX-10R quiz: every answer comes with an explanation and a link to the manual page.