Self-Diagnosis System
Subthrottle Valve Actuator Resistance Inspection
In this manual: Self-Diagnosis System
~1min read
- Turn the ignition switch to OFF.
- Disconnect the subthrottle valve actuator connector [A].

- Connect a digital meter to the subthrottle valve actuator connector [A].
- Measure the subthrottle valve actuator resistance.
Subthrottle Valve Actuator Resistance Connections: Y/BK lead [1] ←→ P/BL lead [2] G lead [3] ←→ BK/O lead [4] Standard: About 6.3
9.5 Ω

If the reading is out of the standard, replace the throttle body assy.
If the reading is within the standard, check the input voltage (see Subthrottle Valve Actuator Input Voltage Inspection).