Heating, Ventilation, and Air Conditioning
Heater and Air Conditioning Control Unit (Dual) Components and Component Locations
In this manual: Heating, Ventilation, and Air Conditioning
~2min read
Components (1)
Control Panel (Dual Heater & A/C Control Module - A)
| Connector | PIN NUMBER | Function | Connector | PIN NUMBER | Function |
| Connector (A) | 1 | BATT+ (TAIL) | Connector (A) | 29 | ECV (+) |
| 2 | SENSOR SUPPLY (+5 V) | 30 | ECV (-) (Ground) | ||
| 3 | HAZARD SIGNAL | 31 | PHOTO SENSOR (-) - LEFT | ||
| 4 | ACC | 32 | PHOTO SENSOR (-) - RIGHT | ||
| 5 | ACTUATOR MODE (VENT) | 33 | HTD | ||
| 6 | ACTUATOR MODE (DEF) | 34 | REAR FOG LAMP SWITCH | ||
| 7 | ACTUATOR F/B MODE | 35 | C-CAN | ||
| 8 | ACTUATOR INTAKE (FRE) | 36 | - | ||
| 9 | INTAKE ACTUATOR (REC) | 37 | PTC ON SIGNAL | ||
| 10 | INTAKE ACTUATOR F/B | 38 | PTC RELAY 2 | ||
| 11 | TEMP ACT''R (COOL)-DIVER | 39 | PTC RELAY 3 | ||
| 12 | TEMP ACTUATOR (HOT) - DRIVER | 40 | SENSOR GROUND | ||
| 13 | TEMP ACT'R F/B-DIVER | Connector (B) | 1 | GROUND | |
| 14 | TEMP ACTUATOR (COOL) - PASSENGER | 2 | - | ||
| 15 | TEMP ACTUATOR (WARM) - PASSENGER | 3 | DEF ACTUATOR (CLOSED) | ||
| 16 | TEMP ACT''R F/B-PASSENGER | 4 | DEF ACTUATOR (OPEN) | ||
| 17 | C_CAN HIGH | 5 | DEF ACT''R F/B | ||
| 18 | C_CAN LOW | 6 | HUMIDITY (PWM) | ||
| 19 | DELAY (+) | 7 | - | ||
| 20 | ILL- (REO) | 8 | IGN2 | ||
| 21 | ION SIGNAL | 9 | GROUND | ||
| 22 | CLEAN SIGNAL | 10 | - | ||
| 23 | IONIZER DIAGNOSIS | 11 | BLOWER MOTOR (+) | ||
| 24 | - | 12 | PT (GATE) | ||
| 25 | - | 13 | FET (DRAIN F/B) | ||
| 26 | AMBIENT SENSOR (+) | 14 | ISG-DC | ||
| 27 | - | 15 | IGN1 | ||
| 28 | EVAPORATOR SENSOR (+) | 16 | BATT |
Components (2)
Control Panel (Dual Heater & A/C Control Module - B)
| Connector | PIN NUMBER | Function | Connector | PIN NUMBER | Function |
| Connector (A) | 1 | BATT+ (TAIL) | Connector (A) | 29 | ECV (+) |
| 2 | SENSOR SUPPLY (+5 V) | 30 | ECV (-) (Ground) | ||
| 3 | HAZARD SIGNAL | 31 | PHOTO SENSOR (-) - LEFT | ||
| 4 | - | 32 | PHOTO SENSOR (-) - RIGHT | ||
| 5 | ACTUATOR MODE (VENT) | 33 | HTD | ||
| 6 | ACTUATOR MODE (DEF) | 34 | REAR FOG LAMP SWITCH | ||
| 7 | ACTUATOR F/B MODE | 35 | C-CAN | ||
| 8 | ACTUATOR INTAKE (FRE) | 36 | - | ||
| 9 | INTAKE ACTUATOR (REC) | 37 | PTC ON SIGNAL | ||
| 10 | INTAKE ACTUATOR F/B | 38 | PTC RELAY 2 | ||
| 11 | TEMP ACT''R (COOL)-DIVER | 39 | PTC RELAY 3 | ||
| 12 | TEMP ACTUATOR (HOT) - DRIVER | 40 | SENSOR GROUND | ||
| 13 | TEMP ACT'R F/B-DIVER | Connector (B) | 1 | GROUND | |
| 14 | TEMP ACTUATOR (COOL) - PASSENGER | 2 | - | ||
| 15 | TEMP ACTUATOR (WARM) - PASSENGER | 3 | DEF ACTUATOR (CLOSED) | ||
| 16 | TEMP ACT''R F/B-PASSENGER | 4 | DEF ACTUATOR (OPEN) | ||
| 17 | C_CAN HIGH | 5 | DEF ACT''R F/B | ||
| 18 | C_CAN LOW | 6 | HUMIDITY (PWM) | ||
| 19 | DELAY (+) | 7 | - | ||
| 20 | ILL- (REO) | 8 | IGN2 | ||
| 21 | ION SIGNAL | 9 | GROUND | ||
| 22 | CLEAN SIGNAL | 10 | - | ||
| 23 | IONIZER DIAGNOSIS | 11 | BLOWER MOTOR (+) | ||
| 24 | MM_CAN HIGH | 12 | PT (GATE) | ||
| 25 | MM_CAN LOW | 13 | FET (DRAIN F/B) | ||
| 26 | AMBIENT SENSOR (+) | 14 | ISG-DC | ||
| 27 | - | 15 | IGN1 | ||
| 28 | EVAPORATOR SENSOR (+) | 16 | BATT |