Electrical & Power Control

Charging System Preliminary Inspection

~1min read

Inspection Procedure

CHECK 12V BATTERY TERMINALS CONNECTION

Check if 12V battery terminals are clean and tight.

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair 12V battery terminals connection.

CHECK “B” TERMINAL CONNECTION

Check if “B” terminal (alternator ground harness) is clean and tight.

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair “B” terminal connection.

CHECK 12V BATTERY STATUS

Check 12V battery status. Refer to Work Flow.

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Replace 12V battery. Refer to Removal and Installation.

CHECK DRIVE BELT TENSION

Check drive belt tension. Refer to Inspection.

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

Repair as needed.