Door & Lock type 2
IGN off interlock door unlock function does not operate
In this manual: Door & Lock type 2
~1min read
Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mode.
3. Check “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT”.
Refer to DLK-217, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (Without Super Lock)".
Is the inspection result normal? YES >> GO TO 2.
NO >> Set “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT”.
2.CHECK “AUTOMATIC DOOR UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT” mode.3. Check “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT”.
Refer to DLK-217, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (Without Super Lock)".
Is the inspection result normal? YES >> GO TO 3.
NO >> Set “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT”.
3.REPLACE BCM 1. Replace BCM. Refer to BCS-93, "Removal and Installation".2. Confirm the operation after replacement.
Is the result normal? YES >> INSPECTION END
NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".