Diagnosis Procedure 1.CHECK FUSES AND FUSIBLE LINK



Check that the following IPDM E/R fuses or fusible links are not blown.

Is the fuse fusing? YES >> Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown.
NO >> GO TO 2.
2.CHECK POWER SUPPLY CIRCUIT 1. Turn the ignition switch OFF. 2. Disconnect IPDM E/R connector.3. Check voltage between IPDM E/R harness connector and the ground.

Is the measurement value normal? YES >> GO TO 3.
NO >> Repair the harness or connector.
3.CHECK GROUND CIRCUITCheck continuity between IPDM E/R harness connectors and the ground.

Does continuity exist? YES >> INSPECTION END
NO >> Repair the harness or connector.