CHECK FUSE
Check that the following fuse are not blown.
| Signal name | Fuse No. |
|---|---|
| Battery power supply | 25 |
| Ignition power supply | 31 |
Is the fuse blown (open)?
YES>>Replace the blown fuse after repairing the affected circuit if a fuse is blown.
NO>>GO TO 2.
CHECK POWER SUPPLY CIRCUIT
Turn the ignition switch OFF.
Disconnect the connector of 3CH CAN gateway.
Check voltage between 3CH CAN gateway harness connector and ground.
Terminals Condition Voltage
(Standard)Voltage
(Reference value)(+) (−) 3CH CAN gateway Ground Ignition switch Connector Terminal M5 8 OFF 6 – 16 V Battery
voltage5 ON 7 – 16 V Battery
voltage
Is the measurement value normal?
YES>>GO TO 3.
NO>>Repair harness or connector.
CHECK GROUND CIRCUIT
Check continuity between 3CH CAN gateway harness connector and ground.
| 3CH CAN gateway | Ground | Continuity | |
| Connector | Terminal | ||
| M5 | 6 | Existed | |
| 7 | |||
Does continuity exist?
YES>>INSPECTION END
NO>>Repair harness or connector.