Torque Converter and Drive Plate
Inspection
INSPECTION
PROCEDURE
1. INSPECT TORQUE CONVERTER ASSEMBLY
(a) Inspect the one-way clutch. (1) Press the stator spline with a finger and rotate it. Check that the spline rotates smoothly clockwise and rotates with difficulty counterclockwise. If necessary, clean the torque converter assembly and inspect the one-way clutch again. Replace the torque converter assembly if the one-way clutch inspection still fails. |
|
(b) Inspect the torque converter assembly. If any of the following conditions is found, replace the torque converter assembly. Malfunction:
HINT: The sample shows approximately 0.025 liter (0.026 US qt, 0.022 Imp. qt) of fluid in a petri dish, taken from the torque converter assembly. |
|
(c) Replace the fluid in the torque converter assembly.
HINT:
If the fluid is discolored or has a burnt odor, agitate the fluid in the torque converter assembly and drain it before replacing the fluid.
(d) Take all necessary precautions to avoid deforming the torque converter assembly and damaging the oil pump drive gear. NOTICE: Make sure all bolts are the same length and the specified bolts are used. HINT: If there is no damage to the bolt end of the torque converter assembly or the bottom of the bolt hole, replace the bolt and the torque converter assembly. |
|
2. INSPECT DRIVE PLATE AND RING GEAR SUB-ASSEMBLY
(a) Check the drive plate for damage.
(b) Set a dial indicator and measure the runout at 6 points on the drive plate surface that contact the torque converter assembly.
![]() |
Measurement point |
Maximum out-of-round:
0.30 mm (0.0118 in.)
If the runout exceeds the maximum or the drive plate is damaged, replace the drive plate.
Click here![]()



.png)