INSPECTION

PROCEDURE

1. INSPECT LH INNER LAMP ASSEMBLY NO. 1

(a) Check that the LED lights up.

(1) Apply battery voltage to the LH inner lamp assembly No. 1 and check that the LED illuminates.

OK:

Measurement Condition

Specified Condition

Battery positive terminal (+) → 1 (+)

Battery negative terminal (-) → 2 (-)

LED lights up

If the result is not as specified, replace the LH inner lamp assembly No. 1.

*a

Component without wire harness connected

(LH Inner Lamp Assembly No. 1)

2. INSPECT RH INNER LAMP ASSEMBLY NO. 1

(a) Check that the LED lights up.

(1) Apply battery voltage to the RH inner lamp assembly No. 1 and check that the LED illuminates.

OK:

Measurement Condition

Specified Condition

Battery positive terminal (+) → 1 (+)

Battery negative terminal (-) → 2 (-)

LED lights up

If the result is not as specified, replace the RH inner lamp assembly No. 1.

*a

Component without wire harness connected

(RH Inner Lamp Assembly No. 1)