Interior Light

Inspection

~2min read

INSPECTION

PROCEDURE

1. INSPECT READING LIGHT ASSEMBLY

(a) Inspect the reading light.

(1) Apply battery voltage to the reading light assembly and check that the reading light illuminates.

OK:

Battery connection

Ignition switch position

Specified Condition

Battery positive (+) → 12 (+B1)

Battery negative (-) → 3 (GND)

LH reading light switch in ON position

LH reading light illuminates

LH reading light switch in OFF position

LH reading light does not illuminate

RH reading light switch in ON position

RH reading light illuminates

RH reading light switch in OFF position

RH reading light does not illuminate

Battery positive (+) → 12 (+B1)

Battery negative (-) → 10 (DOOR)

Reading light switch in OFF position and door switch in ON position

Reading light illuminates

Reading light switch in OFF position and door switch in OFF position

Reading light does not illuminate

If the result is not as specified, replace the bulb or reading light assembly.

*a

Component without wire harness connected

(reading light assembly)

(b) Inspect the door switch.

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Ignition switch position

Specified Condition

10 (DOOR) - 4 (RLMP)

Door switch in ON position

Below 1 Ω

Door switch in OFF position

10 kΩ minimum

If the result is not as specified, replace the reading light assembly.

(c) Inspect the light switch.

(1) Apply battery voltage to the reading light assembly and check that the light illuminates.

OK:

Battery connection

Specified Condition

Battery positive (+) → 2 (ILLB)

Battery negative (-) → 3 (GND)

Light operates

If the result is not as specified, replace the reading light assembly.