Seats

Inspection

~2min read

INSPECTION

PROCEDURE

1. INSPECT LH FRONT SEAT BACK HEATER ASSEMBLY

(a) Made by TMC:

(1) Check the resistance.

  1. Measure the resistance according to the value(s) specified in the table below.

    Standard resistance:

    Tester Connection

    Condition

    Specified Condition

    1 - 2

    Seat heater temperature of 20 °C

    3,11 à 3,73 Ω

    If the result is not as specified, replace the LH front seat back heater assembly.

*a

Component without wire harness connected

(LH front seat back heater assembly)

(b) Made by TMMT:

(1) Check the resistance.

  1. Measure the resistance according to the value(s) specified in the table below.

    Standard resistance:

    Tester Connection

    Condition

    Specified Condition

    1 - 2

    Seat heater temperature of 20 °C

    2,59 à 3,15 Ω

    If the result is not as specified, replace the LH front seat back heater assembly.

*a

Component without wire harness connected

(LH front seat back heater assembly)

2. INSPECT RH FRONT SEAT BACK HEATER ASSEMBLY

(a) Made by TMC:

(1) Check the resistance.

  1. Measure the resistance according to the value(s) specified in the table below.

    Standard resistance:

    Tester Connection

    Condition

    Specified Condition

    1 - 2

    Seat heater temperature of 20 °C

    3,11 à 3,73 Ω

    If the result is not as specified, replace the RH front seat back heater assembly.

*a

Component without wire harness connected

(RH front seat back heater assembly)

(b) Made by TMMT:

(1) Check the resistance.

  1. Measure the resistance according to the value(s) specified in the table below.

    Standard resistance:

    Tester Connection

    Condition

    Specified Condition

    1 - 2

    Seat heater temperature of 20 °C

    2,59 à 3,15 Ω

    If the result is not as specified, replace the RH front seat back heater assembly.

*a

Component without wire harness connected

(RH front seat back heater assembly)