Electrical Distribution
Inspection
INSPECTION
PROCEDURE
1. INSPECT NO. 1 INTEGRATION RELAY
(a) IG1 NO. 3 RELAY:
(1) Measure the resistance according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
1A-4 - 1A-3 |
Battery voltage is not applied between terminals 1A-2 and 1A-1 |
10 kΩ minimum |
Battery positive (+) → 1A-2
Battery negative (-) → 1A-1 |
Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay. |
 |
*a |
Component without wire harness connected
(No. 1 Integration Relay) |
|
|
(b) H-LP LH RELAY:
(1) Measure the resistance according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
1A-5 - 1B-1 |
Battery voltage is not applied between terminals 1A-5 and 1B-2 |
10 kΩ minimum |
Battery positive (+) → 1A-5
Battery negative (-) → 1B-2 |
Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay. |
 |
*a |
Component without wire harness connected
(No. 1 Integration Relay) |
|
|
(c) EFI MAIN RELAY:
(1) Measure the resistance according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
1B-3 - 1B-4 |
Battery voltage is not applied between terminals 1B-5 and 1B-6 |
10 kΩ minimum |
Battery positive (+) → 1B-5
Battery negative (-) → 1B-6 |
Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay. |
 |
*a |
Component without wire harness connected
(No. 1 Integration Relay) |
|
|
(d) IG2 NO. 1 RELAY:
(1) Measure the resistance according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
1A-10 - 1A-9 |
Battery voltage is not applied between terminals 1A-7 and 1A-8 |
10 kΩ minimum |
Battery positive (+) → 1A-7
Battery negative (-) → 1A-8 |
Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay. |
 |
*a |
Component without wire harness connected
(No. 1 Integration Relay) |
|
|
(e) H-LP RH RELAY:
(1) Measure the resistance according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
1B-8 - 1A-12 |
Battery voltage is not applied between terminals 1B-8 and 1A-11 |
10 kΩ minimum |
Battery positive (+) → 1B-8
Battery negative (-) → 1A-11 |
Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay. |
 |
*a |
Component without wire harness connected
(No. 1 Integration Relay) |
|
|
(f) P-CON RELAY:
(1) Measure the resistance according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
1B-9 - 1B-10 |
Battery voltage is not applied between terminals 1B-11 and 1B-12 |
10 kΩ minimum |
Battery positive (+) → 1B-11
Battery negative (-) → 1B-12 |
Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay. |
 |
*a |
Component without wire harness connected
(No. 1 Integration Relay) |
|
|
Was this page helpful?