1ar-fe Cooling
Inspection
In this manual: 1ar-fe Cooling
~1min read
INSPECTION PROCEDURE
1. INSPECT THERMOSTAT
HINT:
The valve opening temperature is inscribed on the thermostat.
(a) Immerse the thermostat in water, and then gradually heat the water. |
![]() |
(b) Check that the valve of the thermostat opens at the specified temperature.
Standard valve opening temperature:
80 to 84 °C
If the valve does not open as specified, replace the thermostat.
(c) Check the valve lift. Standard valve lift: 10 mm (0.394 in.) or more at 95 °C If the valve lift is not as specified, replace the thermostat. |
![]() |
(d) Check that the valve is fully closed when the thermostat is at a low temperature (below 77 °C).
If the valve is not fully closed, replace the thermostat.