Coolant Repair procedures
Refilling And Bleeding
Remove the inverter reservoir cap (A) to help drain the coolant faster.

Remove the under cover.
(Refer to Engine Mechanical System - "Engine Room Under Cover")
Remove the drain plug (A), allow the coolant to drain out and then reinstall the drain plug.
Tightening torque : 7.8 - 11.8 N.m (0.7 - 1. 4 kgf.m, 5.8 - 8.7 lb-ft)

After draining coolant from the reservoir tank, clean the tank.
Fill the radiator with water through the inverter reservoir cap and tighten the cap.
Switch "ON" the ignition and then perform the EWP actuation using KDS/GDS.

Repeat steps 1 to 6 until the drained water runs clear.
Fill the reservoir with coolant. Slowly fill with the fluid mixture of coolant and water (45 - 50%).
Perform the EWP actuation using KDS/GDS.

While the EWP operates and coolant circulates, refill coolant so that the coolant level is kept between "MAX" and "MIN" levels.
Air bleeding procedure of the coolant system is completed when the EWP operating sound gets lower and no more air bubbles are seen from the reservoir. (It would take about 3 - 5 minutes.)
After air bleeding, stop the EWP, add coolant to the "MAX" level, and install the reservoir cap.