Hybrid Motor System

Electric Water Pump (EWP) Repair procedures

7steps
~42min
2/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 7

Removal

  1. Disconnect the negative (-) cable of the 12V battery.

  2. Remove the under cover.

    (Refer to Engine Mechanical System - "Engine Room Under Cover")

  3. Drain the coolant of hybrid motor cooling system.

    (Refer to Hybrid Motor Cooling System - "Coolant")

  4. Separate the hose (A) from the reservoir.

  5. Separate the hose (A).

  6. Disconnect the EWP connector (A) and then remove the EWP after removing the bracket (B).

    Tightening torque : 9.8 - 11,8 N·m

  7. Separate the hoses (A, B) from the EWP.

Installation

  1. Install in the reverse order of removal.