Gear Actuator Assembly Repair procedures
Removal
Shut off the high voltage circuit.
(Refer to Automatic Transaxle System - "High Voltage Shut-off Procedure")
Drain the coolant of hybrid cooling system.
(Refer to Hybrid Motor System - "Coolant")
Remove the hybrid power control unit (HPCU) assembly.
(Refer to Hybrid Control System - "Hybrid Power Control Unit")
Disconnect the TCM connector (A) and ECM connector (B).

Remove the TCM (A) and ECM (B).
Tightening torque : 9.8 - 11,8 N·m

Remove the HPCU tray (C) after removing the nut (A) and wiring mounting clips (B).
Tightening torque :
(A) 10.8 - 13,7 N·m
(C) 21.6 - 24 N·m

Disconnect the gear actuator motor connector (A) and gear actuator solenoid connector (B).

Remove the gear actuator assembly after loosening bolts (A, B).
Tightening torque :
(A) 19.6 - 26 N·m
(B) 9.8 - 11,8 N·m

Installation
Install in the reverse order of removal.