DCT(Dual Clutch Transmission) System

Shift Cable Repair procedures

25steps
~150min
5/5difficulty
0102030405014.711N·mlb·ft
Tightening torque found on this page
Done 0 of 25

Removal

  1. Place the shift lever in the "N" position.

  2. Shut off the high voltage circuit.

    (Refer to Automatic Transaxle System - "High Voltage Shut-off Procedure")

  3. Drain the coolant of hybrid cooling system.

    (Refer to Hybrid Motor System - "Coolant")

  4. Remove the hybrid power control unit (HPCU) assembly.

    (Refer to Hybrid Control System - "Hybrid Power Control Unit")

  5. Disconnect the TCM connector (A) and ECM connector (B).

  6. Remove the TCM (A) and ECM (B).

  7. Remove the HPCU tray (C) after removing the nut (A) and wiring mounting clips (B).

  8. Loosen the nut (A) and then remove the shift cable (B) from the bracket.

  9. Remove the knob (A) by pulling it in the direction of arrow after removing the boots from the console upper cover.

  10. Remove the floor console assembly.

    (Refer to Body - "Floor Console")

  11. Remove the shift cable.

    1. Remove the shift cable from the shift lever pim after removing the snap pin (A).

    2. Remove the cable socket (B) from the shift lever.

  12. Remove the shift cable retainer (A) after loosening the nuts (B). Then, remove the shift cable by pulling it toward the vehicle interior.

Installation

  1. Check that the shift lever is placed in the "N" position.

  2. Install the shift cable retainer (A) by tightening nuts (B).

    Tightening torque : 11.8 - 14,7 N·m

  3. Install the shift cable.

    1. Install the cable socket (A).

    2. Install the shift cable to the lever pin and then insert the snap pin (A).

  4. Install the floor console assembly.

    (Refer to Body “Floor Console”)

  5. Install the knob (A) by pressing it in the direction of arrow after installing the boots to the console upper cover.

  6. Tighten the nut (A) to the specified torque after removing free play by pushing the shift cable in the direction of the arrow.

    Tightening torque : 8.8 - 13,7 N·m

  7. Install the HPCU tray (A).

    Tightening torque : (A) 21.6 - 24 N·m

  8. Install the wiring mounting clips (B) to HPCU tray and the tighten the nut (C).

    Tightening torque : (C) 10.8 - 13,7 N·m

  9. Install the TCM (A) and ECM (B).

    Tightening torque : 9.8 - 11,8 N·m

  10. Connect the TCM connector (A) and ECM (B) connector.

  11. Install the hybrid power control unit (HPCU) assembly.

    (Refer to Hybrid Control System - "Hybrid Power Control Unit"

  12. Refill the hybrid motor cooling system with coolant.

    (Refer to Hybrid Motor System - "Coolant")

  13. Connect the high voltage circuit.

    (Refer to Automatic Transaxle System - "High Voltage Shut-off Procedure")