Ventilation, Heater & Air Conditioner

Precautions

11steps
~66min
5/5difficulty
Done 0 of 11

Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER"

The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”, used along with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain types of collision.

Information necessary to service the system safely is included in the “SRS AIR BAG” and “SEAT BELT” of this Service Manual.

  • To avoid rendering the SRS inoperative, which could increase the risk of personal injury or death in the event of a collision that would result in air bag inflation, it is recommended that all maintenance and repair be performed by an authorized NISSAN/INFINITI dealer.

  • Improper repair, including incorrect removal and installation of the SRS, can lead to personal injury caused by unintentional activation of the system. For removal of Spiral Cable and Air Bag Module, see “SRS AIR BAG”.

  • Never use electrical test equipment on any circuit related to the SRS unless instructed to in this Service Manual. SRS wiring harnesses can be identified by yellow and/or orange harnesses or harness connectors.

PRECAUTIONS WHEN USING POWER TOOLS (AIR OR ELECTRIC) AND HAMMERS

  • When using air or electric power tools or hammers, always switch the ignition/power switch OFF, disconnect the 12V battery or batteries, and wait at least 3 minutes before performing any service.

Precaution for Procedure without Cowl Top Cover

When performing the procedure after removing cowl top cover, cover the lower end of windshield with urethane, etc to prevent damage to windshield.

Precautions for Removing Battery Terminal

  • When disconnecting the 12V battery terminal, turn off the ACC power before disconnecting the 12V battery terminal, observing “How to disconnect 12V battery terminal” described below.

  • For Nissan Armada vehicles with the 2-batteries, be sure to connect the main battery and the sub battery before turning ON the ignition switch.

  • After installing the 12V battery, always check "Self Diagnosis Result" of all ECUs and erase DTC.

HOW TO DISCONNECT 12V BATTERY TERMINAL

Disconnect 12V battery terminal according to instruction described below.

  1. Open the hood.

  2. Turn ignition switch to the ON position.

  3. Turn ignition switch to the OFF position with the driver side door opened.

  4. Get out of the vehicle and close the driver side door.

  5. Wait at least 3 minutes. For vehicle with the engine listed below, remove the battery terminal after a lapse of the specified time.

    BR08DE : 4 minutes R9N engine : 12 minutes
    BR10DE : 12 minutes V9X engine : 4 minutes
    D4D engine : 20 minutes YD25DDTi : 2 minutes
    HR09DET : 12 minutes YS23DDT : 4 minutes
    HR10DDT : 12 minutes YS23DDTT : 4 minutes
    HR10DET : 12 minutes ZD30DDTi : 60 seconds
    HR13DDT : 12 minutes ZD30DDTT : 60 seconds
    HRA2DDT : 12 minutes K9K engine : 4 minutes
    M9R engine : 4 minutes R9M engine : 4 minutes
  6. Remove 12V battery terminal.

Precaution for when Jacking and Lifting Up the Vehicle with Electronic Air Suspension System

OPERATION PROCEDURE

Jacking up or lift up using the following steps.

  1. Start engine.

  2. Turn auto height mode control switch to ON, shift the shift position to N and set to normal height.

  3. Turn OFF the electronic air suspension function. Refer to Operation.

  4. Stop engine.

  5. Jacking up or lift up.

Precaution for Electronic Air Suspension System

Precautions For Refrigerant System Service

GENERAL REFRIGERANT PRECAUTION

WORKING WITH HFO-1234yf (R-1234YF)

CONTAMINATED REFRIGERANT

Take appropriate steps shown below if a refrigerant other than pure HFO-1234yf (R-1234yf) is identified in a vehicle:

  • Explain to the customer that environmental regulations prohibit the release of contaminated refrigerant into the atmosphere.

  • Explain that recovery of the contaminated refrigerant could damage service equipment and refrigerant supply.

  • Suggest the customer return the vehicle to the location of previous service where the contamination may have occurred.

  • In case of repairing, recover the refrigerant using only dedicated equipment and containers. Never recover contaminated refrigerant into the existing service equipment. Contact a local refrigerant product retailer for available service if the facility does not have dedicated recovery equipment. This refrigerant must be disposed of in accordance with all federal and local regulations. In addition, replacement of all refrigerant system components on the vehicle is recommended.

  • The air conditioner warranty is void if the vehicle is within the warranty period. Please contact Nissan Customer Affairs for further assistance.

REFRIGERANT CONNECTION

  • Store it in the same way at it is when mounted on the car when the A/C compressor is removed. Failure to do so will cause lubricant to enter the low-pressure chamber.

  • Use always a torque wrench and a back-up wrench when connecting tubes.

  • Plug immediately all openings to prevent entry of dust and moisture after disconnecting tubes.

  • Connect the pipes at the final stage of the operation when installing an air conditioner in the vehicle. Never remove the seal caps of pipes and other components until just before required for connection.

  • Allow components stored in cool areas to warm to working area temperature before removing seal caps. This prevents condensation from forming inside A/C components.

  • Remove thoroughly moisture from the refrigeration system before charging the refrigerant.

  • Replace always used O-rings.

  • Apply lubricant to circle of the O-rings shown in illustration when connecting tube. Be careful not to apply lubricant to threaded portion.

  • O-ring must be closely attached to the groove portion of tube.

  • Be careful not to damage O-ring and tube when replacing the O-ring.

  • Connect tube until a click can be heard. Then tighten the nut or bolt by hand. Check that the O-ring is installed to tube correctly.

  • Perform leakage test and make sure that there is no leakage from connections after connecting line. Disconnect that line and replace the O-ring when the refrigerant leaking point is found. Then tighten connections of seal seat to the specified torque.

A/C COMPRESSOR

Service Equipment

RECOVERY/RECYCLING RECHARGING EQUIPMENT

Be certain to follow the manufacturer’s instructions for machine operation and machine maintenance. Never introduce any refrigerant other than that specified into the machine.

ELECTRICAL LEAK DETECTOR

Be certain to follow the manufacturer’s instructions for tester operation and tester maintenance.

VACUUM PUMP

The lubricant contained inside the vacuum pump is not compatible with the specified lubricant for HFO-1234yf (R-1234yf) A/C systems. The vent side of the vacuum pump is exposed to atmospheric pressure. So the vacuum pump lubricant may migrate out of the pump into the service hose. This is possible when the pump is switched OFF after evacuation (vacuuming) and hose is connected to it.

To prevent this migration, use a manual valve placed near the hose-to-pump connection, as per the following.

  • Vacuum pumps usually have a manual isolator valve as part of the pump. Close this valve to isolate the service hose from the pump.

  • Use a hose equipped with a manual shut-off valve near the pump end for pumps without an isolator. Close the valve to isolate the hose from the pump.

  • Disconnect the hose from the pump if the hose has an automatic shut-off valve. As long as the hose is connected, the valve is open and lubricating oil may migrate.

Some one-way valves open when vacuum is applied and close under no vacuum condition. Such valves may restrict the pump’s ability to pull a deep vacuum and are not recommended.

MANIFOLD GAUGE SET

Be certain that the gauge face indicates HFO-1234yf or R-1234yf. Be sure the gauge set has threaded connections for HFO-1234yf (R-1234yf) service hoses. Confirm the set has been used only with refrigerant HFO-1234yf (R-1234yf) and specified lubricants.

SERVICE HOSES

All hoses must equip positive shut-off devices (either manual or automatic) near the end of the hoses opposite to the manifold gauge.

SERVICE COUPLERS

Never attempt to connect HFO-1234yf (R-1234yf) service couplers to the CFC-12 (R-12) and HFC-134a (R-134a) A/C system. The HFO-1234yf (R-1234yf) couplers do not properly connect to the CFC-12 (R-12) and HFC-134a (R-134a) system. However, if an improper connection is attempted, discharging and contamination may occur.

Shut-off valve rotationA/C service valve
Clockwise Open
Counterclockwise Close

REFRIGERANT WEIGHT SCALE

Verify that no refrigerant other than HFO-1234yf (R-1234yf) and specified lubricants have been used with the scale. The hose fitting must be 1/2″-16 ACME if the scale controls refrigerant flow electronically.

CHARGING CYLINDER

Using a charging cylinder is not recommended. Refrigerant may be vented into air from cylinder’s top valve when filling the cylinder with refrigerant. Also, the accuracy of the cylinder is generally less than that of an electronic scale or of quality recycle/recharge equipment.