Ventilation, Heater & Air Conditioner

Refrigerant

~6min read

Description

CONNECTION OF SERVICE TOOLS AND EQUIPMENT

Be certain to follow the manufacturer’s instructions for connecting to the machine.

Leak Test

CHECK REFRIGERANT LEAKAGE USING ELECTRICAL LEAK DETECTOR

  • Never allow refrigerant vapor, shop chemical vapors, cigarette smoke, or others around the vehicle.

  • Always check refrigerant leakage in a low air flow environment so that refrigerant may not disperse when leakage occurs.

Stop the engine.

Connect recovery/recycling/recharging equipment or manifold gauge set to A/C service valve.

Check that A/C refrigerant pressure is 345 kPa (3.52 kg/cm2, 50 psi) or more when temperature is 16 °C or more. When pressure is lower than the specified value, recycle refrigerant completely and fill refrigerant to the specified level.

Clean area where refrigerant leakage check is performed, and check refrigerant leakage along all surfaces of pipe connections and A/C system components using electrical leak detector probe.

Repair or replace parts where refrigerant leakage is detected. (Leakage is detected but leakage area is unknown. GO TO 6.)

Start the engine and set A/C control in the following conditions.

  • A/C switch ON

  • Air flow: VENT (ventilation)

  • Intake door position: Recirculation

  • Temperature setting: Full cold

  • Fan (blower) speed: Maximum speed set

Run the engine at approximately 1,500 rpm for 2 minutes or more.

Stop the engine. Check again for refrigerant leakage. GO TO 4.

Recycle Refrigerant

Perform lubricant return operation. Refer to Perform Lubricant Return Operation. (If refrigerant or lubricant leakage is detected in a large amount, omit this step, and then GO TO 2.)

Check gauge pressure readings of recovery/recycling/recharging equipment. When remaining pressure exists, recycle refrigerant from high-pressure hose and low-pressure hose.

Remove A/C service valve cap from the vehicle.

Connect recovery/recycling/recharging equipment to A/C service valve.

Operate recovery/recycling/recharging equipment, and recycle refrigerant from the vehicle.

Evacuate air for 10 minutes or more to remove any remaining refrigerant integrated to compressor lubricant, etc.

Refrigerant recycle operation is complete.

Charge Refrigerant

Connect recovery/recycling/recharging equipment to the A/C service valve.

Operate recovery/recycling/recharging equipment, and evacuate air from A/C system for 25 minutes or more.

Check the airtightness of A/C system for 25 minutes or more. If pressure raises more than the specified level, charge A/C system with approximately 200 g (7.05 oz) refrigerant and check that there is no refrigerant leakage. Refer to Leak Test.

If parts other than A/C compressor are replaced, fill compressor lubricant according to parts that are replaced.

Charge the specified amount of refrigerant to A/C system.

Check that A/C system operates normally.

Disconnect recovery/recycling/recharging equipment. (Collect the refrigerant from the high-pressure hose and low-pressure hose of recovery/recycling/recharging equipment.)

Install A/C service valve cap.

Refrigerant charge is complete.