Push-button ignition switch
Component Function Check
1.CHECK FUNCTION 1. Select “PUSH SW” in “Data Monitor” mode with CONSULT-III.2. Check the push-button ignition switch signal under the following conditions.

Is the indication normal? YES >> INSPECTION END.
NO >> Go to PCS-108, "Diagnosis Procedure".
Diagnosis Procedure
1.CHECK PUSH-BUTTON IGNITION SWITCH OUTPUT SIGNAL 1 1. Turn ignition switch OFF. 2. Disconnect push-button ignition switch connector and IPDM E/R connector.3. Check voltage between push-button ignition switch harness connector and ground.

Is the inspection result normal? YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT 1 1. Disconnect BCM connector.2. Check continuity between BCM harness connector and push-button ignition switch harness connector.

3. Check continuity between BCM harness connector and ground.

Is the inspection result normal? YES >> Replace BCM. Refer to BCS-93, "Removal and Installation".
NO >> Repair or replace harness.
3.CHECK PUSH-BUTTON IGNITION SWITCH OUTPUT SIGNAL 2Check voltage between IPDM E/R harness connector and ground.

Is the inspection result normal? YES >> GO TO 5.
NO >> GO TO 4.
4.CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT 2 1. Disconnect BCM connector.2. Check continuity between IPDM E/R harness connector and push-button ignition switch harness connector.

3. Check continuity between IPDM E/R harness connector and ground.

Is the inspection result normal? YES >> Replace IPDM E/R.
NO >> Repair or replace harness.
5.CHECK PUSH-BUTTON IGNITION SWITCH GROUND CIRCUITCheck continuity between push-button ignition switch harness connector and ground

Is the inspection result normal? YES >> GO TO 6.
NO >> Repair or replace harness.
6.CHECK PUSH-BUTTON IGNITION SWITCHRefer to PCS-109, "Component Inspection".
Is the inspection result normal? YES >> GO TO 7.
NO >> Replace push-button ignition switch.
7.CHECK INTERMITTENT INCIDENTRefer to GI-42, "Intermittent Incident".
>> INSPECTION END
Component Inspection
1.CHECK PUSH-BUTTON IGNITION SWITCH 1. Turn ignition switch OFF. 2. Disconnect push-button ignition switch connector.3. Check continuity between push-button ignition switch terminals.

Is the inspection result normal? YES >> INSPECTION END
NO >> Replace push-button ignition switch.