Electrical & Power Control

Abs Branch Line Circuit

5steps
~30min
2/5difficulty
Done 0 of 5
Diagnosis Procedure

CHECK CONNECTOR

  1. Turn the ignition switch OFF.

  2. Disconnect the battery cable from the negative terminal.

  3. Check the terminals and connectors of the ABS actuator and electric unit (control unit) for damage, bend and loose connection (unit side and connector side).

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair the terminal and connector.

CHECK HARNESS FOR OPEN CIRCUIT

  1. Disconnect the connector of ABS actuator and electric unit (control unit).

  2. Check the resistance between the ABS actuator and electric unit (control unit) harness connector terminals.

    ABS actuator and electric unit (control unit) harness connector Resistance (Ω)
    Connector No. Terminal No.
    E125 26 14 Approx. 54 – 66

Is the measurement value within the specification?

YES>>

GO TO 3.

NO>>

Repair the ABS actuator and electric unit (control unit) branch line.

CHECK POWER SUPPLY AND GROUND CIRCUIT

Check the power supply and the ground circuit of the ABS actuator and electric unit (control unit). Refer to Diagnosis Procedure.

Is the inspection result normal?

YES>>

Replace the ABS actuator and electric unit (control unit). Refer to Removal and Installation.

YES>>

Error was detected in the ABS actuator and electric unit (control unit) branch line.

NO>>

Repair the power supply and the ground circuit.