Electrical & Power Control

B Terminal Circuit

4steps
~24min
2/5difficulty
Done 0 of 4
Diagnosis Procedure

CHECK TERMINAL "B" CONNECTION

  1. Ignition switch OFF.

  2. Verify terminal “B” is clean and tight.

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair terminal “B” connection. Confirm repair by performing system test using 165-DSS-5000P. Refer to the applicable instruction manual for proper testing procedures.

CHECK TERMINAL "B" CIRCUIT

Check voltage between generator connector and ground.

(+)(—)

Voltage

(Approx.)
Generator
ConnectorTerminal
F6 1 Ground Battery voltage

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Check harness for open between generator and fusible link.

CHECK TERMINAL "B" CONNECTION (VOLTAGE DROP TEST)

  1. Start engine, engine should be running at idle and warm.

  2. Check voltage between battery positive terminal and generator connector.

    (+)(—)

    Voltage

    (Approx.)
    Generator
    ConnectorTerminal
    F6 1 Battery positive terminal Less than 0.2 V

Is the inspection result normal?

YES>>

Terminal “B” circuit is normal. Refer to Work Flow (With 165-DSS-5000P), or (Without 165-DSS-5000P).

NO>>

Check harness between battery and generator for high resistance.