Electrical & Power Control
Charging System Preliminary Inspection
In this manual: Electrical & Power Control
~1min read
CHECK BATTERY TERMINAL CONNECTIONS
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair battery terminals connection. Confirm repair by performing system test using 165-DSS-5000P. Refer to the applicable instruction manual for proper testing procedures.
CHECK FUSE AND FUSIBLE LINK
Check for blown fuse and fusible link.
| Unit | Power source (Power supply terminals) | Fuse or Fusible Link No. | Capacity |
|---|---|---|---|
| Generator | Battery (terminal 3) | 59 | 10 A |
| Battery (terminal 1) | A | 250 A | |
| Combination meter | Ignition switch ON or START (terminal 2) | 31 | 5 A |
Is the fuse or fusible link blown?
YES>>Replace the blown fuse or fusible link after repairing the affected circuit.
NO>>GO TO 3.
CHECK GENERATOR GROUND
Check if generator case ground is clean.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair connection.
CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to Inspection.
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair as needed.