L Terminal Circuit (open)
CHECK "L" TERMINAL CONNECTION
Ignition switch OFF.
Check if "L" terminal is clean and tight.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair "L" terminal connection. Confirm repair by performing system test using 165-DSS-5000P. Refer to applicable instruction manual for proper testing procedures.
CHECK “L” TERMINAL CIRCUIT (OPEN)
Disconnect generator connector.
Apply ground generator harness connector.
Check condition of the charge warning lamp with ignition switch in the ON position.
Generator — Condition Connector Terminal Ignition switch Charge warning lamp F7 2 Ground ON Illuminate
Does it illuminate?
YES>>“L” terminal circuit is normal. Refer to Work Flow (With 165-DSS-5000P), or (Without 165-DSS-5000P).
NO>>GO TO 3.
CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Disconnect the battery cable from the negative terminal.
Disconnect combination meter connector and generator connector.
Check continuity between generator harness connector and combination meter harness connector.
Generator Combination meter Continuity Connector Terminal Connector Terminal F7 2 M24 11 Yes
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace the harness or connectors.
CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Check continuity between combination meter harness connector and fuse block (J/B).
| Combination meter | Fuse block (J/B) | Continuity | ||
|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |
| M23 | 44 | M4 | 8P | Yes |
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace the harness or connectors.
CHECK POWER SUPPLY CIRCUIT
Connect the battery cable to the negative terminal.
Check voltage between combination meter harness connector and ground.
(+) (—) Condition Voltage
(Approx.)Combination meter Connector Terminal M23 44 Ground When ignition switch is ON Battery voltage
Is the inspection result normal?
YES>>Replace the combination meter. Refer to Removal and Installation.
NO>>Repair or replace the harness or connectors.