Diagnosis Procedure

CHECK “S” TERMINAL CONNECTION

  1. Ignition switch OFF.

  2. Check if “S” terminal is clean and tight.

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair “S” terminal connection. Confirm repair by performing system test using 165-DSS-5000P. Refer to the applicable Instruction Manual for proper testing procedures.

CHECK “S” TERMINAL CIRCUIT

Check voltage between generator harness connector and ground.

(+)(—)

Voltage

(Approx.)
Generator
ConnectorTerminal
F7 3 Ground Battery voltage

Is the inspection result normal?

YES>>

Refer to Work Flow (With 165-DSS-5000P), or (Without 165-DSS-5000P).

NO>>

Check harness for open between generator and fuse.