Electrical & Power Control
Power Supply and Ground Circuit
In this manual: Electrical & Power Control
4steps
~24min
2/5difficulty
Done 0 of 4
CHECK FUSIBLE LINKS
Check that the following fusible links are not blown:
| Terminal | Signal name | Fusible link No. | Capacity |
|---|---|---|---|
| 1 | Battery power supply | E | 80 A |
| 2 | A | 250 A | |
| C | 80 A | ||
| 3 | A | 250 A | |
| B | 100 A | ||
| N | 40 A |
Is the fusible link blown?
YES>>Replace the blown fusible link after repairing the affected circuit.
NO>>GO TO 2.
CHECK POWER SUPPLY CIRCUIT
Disconnect IPDM E/R connectors.
Check voltage between IPDM E/R harness connectors and ground.
IPDM E/R — Voltage
(Approx.)Connector Terminal E118 1 Ground Battery voltage 2 E120 3
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness or connectors.
CHECK GROUND CIRCUIT
Disconnect IPDM E/R connectors.
Check continuity between IPDM E/R harness connectors and ground.
| IPDM E/R | — | Continuity | |
| Connector | Terminal | ||
| E121 | 7 | Ground | Yes |
| E119 | 41 | ||
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace harness or connectors.