Windows

Relay

~1min read

Inspection On Vehicle

INSPECTION ON VEHICLE

PROCEDURE

1. INSPECT DEFOGGER RELAY

(a) Check the resistance.

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

3 - 4

Battery voltage applied to terminals 1 and 2

10 kΩ minimum

3 - 4

Battery voltage not applied between terminals

Below 1 Ω

3 - 5

Battery voltage applied to terminals 1 and 2

Below 1 Ω

3 - 5

Battery voltage not applied between terminals

10 kΩ minimum

4 - 5

Always

10 kΩ minimum

If the result is not as specified, replace the defogger relay.