Vehicle Interior
Inspection
In this manual: Vehicle Interior
~1min read
INSPECTION
PROCEDURE
1. INSPECT NO. 1 COOLER THERMISTOR
(a) Check the resistance.
(1) Measure the resistance according to the value(s) in the table below.
*a |
Component without harness connected (No. 1 Cooler Thermistor) |
*b |
Sensing Portion |
*c |
Resistance (kΩ) |
*d |
Temperature (°C (°F)) |
*e |
Allowable Range |
- |
- |
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
1 - 2 |
-10°C (14°F) |
7.30 to 9.10 kΩ |
1 - 2 |
-5°C (23°F) |
5.65 to 6.95 kΩ |
1 - 2 |
0 °C |
4.40 to 5.35 kΩ |
1 - 2 |
5 °C |
3.40 to 4.15 kΩ |
1 - 2 |
10 °C |
2.70 to 3.25 kΩ |
1 - 2 |
15 °C |
2.14 to 2.58 kΩ |
1 - 2 |
20 °C |
1.71 to 2.05 kΩ |
1 - 2 |
25 °C |
1.38 to 1.64 kΩ |
1 - 2 |
30 °C |
1.11 to 1.32 kΩ |
NOTICE:
- Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph).
If the resistance is not as specified, replace the No. 1 cooler thermistor.
Was this page helpful?