Electrical system, general information
Repairs to wiring with cross sections up to 0.35 mm2
In this manual: Electrical system, general information
~2min read
Special tools and workshop equipment requiredCrimping pliers, complete -VAS 1978/1 A- |
Head adapter 0.35 mmІ - 2.5 mmІ -VAS 1978/1-1-For repairs to wiring with cross sections up to 0.35 mm2, it is essential that contacts are crimped on using crimping pliers for JPT contacts -VAS 1978/9A- or crimping pliers (base tool) -VAS 1978/1-2- with attached head adapter for JPT contacts -VAS 1978/9-1-. Due to the low current strength of these wires in the micro and thousandths range, incorrectly crimped contacts cause electrical resistances and result in faults or failure in the respective system. The most common applications of these contacts are:Lambda probeEngine speed senderAir mass meterWith the use of crimping pliers for JPT contacts -VAS 1978/9A- or crimping pliers (base tool) -VAS 1978/1-2- with attached head adapter for JPT contacts -VAS 1978/9-1-, the correct connection between crimp contact, wire and single wire seal is assured. The tool is only to be used for the application described. Note Crimped to the repair wiring are normal contacts and gold-plated contacts. The repair contact must always be the same type as the contact installed in the factory. Crimping on new contact with single wire seal
|
![]() |
Note When doing this, the small diameter of the single wire seal must face the contact to be crimped on. |
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
| Successful crimping can be identified by clean and equal application of pressure on the wire and single wire seal in the contact and by a stamp on the rear that indicates the correct tool was used in the correct manner to carry out the crimping process. | ![]() |
Test yourself
A quick Volkswagen Golf quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?
Note Crimped to the repair wiring are normal contacts and gold-plated contacts. The repair contact must always be the same type as the contact installed in the factory. 