Engine Mechanical System

Thermostat Repair procedures

12steps
~72min
3/5difficulty
0102030405023.517N·mlb·ft
Tightening torque found on this page
Done 0 of 12

Removal and Installation

  1. Remove the engine room under cover.

    (Refer to Engine and Transaxle Assembly - "Engine Room Under Cover")

  2. Drain the coolant.

    (Refer to Cooling System - "Coolant")

  3. Disconnect the radiator lower hose (A).

  4. Remove the water inlet fitting (A).

    Tightening torque : 18.6 - 24 N·m

  5. Remove the thermostat (A).

  6. Install in the reverse order of removal.

  7. Fill the engine coolant.

    (Refer to Cooling System - "Coolant")

  8. Start the engine and check for leaks.

  9. Recheck the coolant level.

Inspection

  1. Immerse thermostat in water heated to over 95 °C, then heat for at least 3 minutes to check valve lift.

  2. Check the valve opening temperature.

    If the valve opening temperature is not as specified, replace the thermostat.

    Valve opening temperature :

    88 ± 1,5 °C

    Full opening temperature : 100 °C

  3. Check the valve lift.

    If the valve lift is not as specified, replace the thermostat.

    Valve lift : 8 mm (0.3 in.) or more at 100 °C