Body electrical system
Flasher unit inspection
In this manual: Body electrical system
~1min read
1. Connect the connector to the flasher unit.
2. Connect the negative battery cable.
3. Measure the voltage at the flasher unit using voltmeter.
- When inspecting terminal F for continuity, disconnect the flasher unit connector.
4. If the value are not as specified in the Terminal Voltage List (Reference), inspect the parts under Action and related wiring harnesses.
5. If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the flasher unit.
Terminal Voltage List (Reference)


Test yourself
A quick Mazda 6 quiz: every answer comes with an explanation and a link to the manual page.