Additional Service When Replacing Around View Monitor Control Unit
Description
Perform the following operations when replacing around view monitor control unit. For details, refer to Work Procedure.
AFTER REPLACEMENT
When after replacing around view monitor control unit, the following items must be performed. Or not doing so, around view monitor system does not operate normally.
Writing MAC key
Configuration
Camera calibration
Work Procedure
Perform the following procedures after replacing the around view monitor control unit.
REPLACE AROUND VIEW MONITOR CONTROL UNIT
Replace around view monitor control unit. Refer to Removal and Installation.
>>GO TO 2.
WRITING MAC KEY
With CONSULT
Perform MAC key writing. Refer to Description.
>>GO TO 3.
PERFORM CONFIGURATION
With CONSULT
Perform "Replace ECU".
>>GO TO 4.
WRITING OF CALIBRATION DATA
Write the calibration data stored in the camera using CONSULT. Refer to Work Procedure.
>>GO TO 5.
PERFORM SELF-DIAGNOSIS
Perform the self-diagnosis of around view monitor control unit with CONSULT (AROUND VIEW MONITOR).
Check if any DTC is detected.
Is any DTC detected?
YES>>Perform the trouble diagnosis for the detected DTC. Refer to DTC Index.
NO>>GO TO 6.
OPERATION CHECK
Confirm that the operation of the around view monitor and the camera image (reference line, expected route) are normal.
>>WORK END