Electrical & Power Control
Combination Switch Input Circuit
In this manual: Electrical & Power Control
6steps
~36min
2/5difficulty
Done 0 of 6
CHECK INPUT 1 - 5 SYSTEM CIRCUIT FOR OPEN
Ignition switch OFF.
Disconnect BCM connector and combination switch connector.
Check continuity between BCM harness connector and combination switch harness connector.
Combination switch signal BCM Combination switch Continuity Connector Terminal Connector Terminal INPUT 1 M19 79 M28 11 Yes INPUT 2 78 9 INPUT 3 77 7 INPUT 4 76 10 INPUT 5 75 13
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace harness or connectors.
CHECK INPUT 1 - 5 SYSTEM CIRCUIT FOR SHORT
Check continuity between BCM harness connector and ground.
| Combination switch signal | BCM | Ground | Continuity | |
| Connector | Terminal | |||
| INPUT 1 | M19 | 79 | No | |
| INPUT 2 | 78 | |||
| INPUT 3 | 77 | |||
| INPUT 4 | 76 | |||
| INPUT 5 | 75 | |||
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness or connectors.
CHECK BCM OUTPUT VOLTAGE
Connect BCM connector and combination switch connector.
Ignition switch ON.
Check voltage between BCM connector and ground.
(+) (–) Voltage Combination switch signal BCM Connector Terminal INPUT 1 M19 79 Ground Refer to Reference Value. INPUT 2 78 INPUT 3 77 INPUT 4 76 INPUT 5 75
Is the inspection result normal?
YES>>Replace the combination switch. Refer to Removal and Installation.
NO>>Replace BCM. Refer to Removal and Installation.
Was this page helpful?