Transmission & Driveline

Torque Converter and Converter Housing Oil Seal

~1min read
Exploded View
Transaxle assembly Converter housing oil seal Torque converter
: Always replace after every disassembly.
: Apply CVT Fluid
Disassembly

Remove transaxle assembly. Refer to Removal and Installation (front wheel drive) or Removal and Installation (all wheel drive).

Remove torque converter from transaxle assembly.

Remove converter housing oil seal using suitable tool.

Assembly

Assembly is in the reverse order of disassembly.

Drive converter housing oil seal (1) evenly using oil pump seal installer [SST: KV31500700 (J-50818)] (A) so that converter housing oil seal protrudes by the dimension (B) respectively.

Unit: mm (in)

Commercial service tool: (A) Outer diameter: 65 (2.56)
Inner diameter: 60 (2.36)

  1. : Transaxle assembly

Unit: mm (in)

Dimension (B) 1.0 ± 0.5 (0.039 ± 0.020)

After completing installation, check for CVT fluid leaks and CVT fluid level. Refer to Inspection.

Attach the pawl (A) of the torque converter to the drive sprocket hole (B) on the transaxle assembly side.

Inspection

INSPECTION AFTER INSTALLATION

  • After inserting a torque converter to the CVT, check dimension (A) with in the reference value limit.

    B : Scale
    C : Straightedge
    Dimension (A) : Refer to Torque Converter.