U1302 Camera Power Volt
DTC DETECTION LOGIC
| DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC detection condition | |
|---|---|---|---|
| U1302 | CAMERA POWER VOLT (Camera power voltage) |
Diagnosis condition | When ignition switch is ON |
| Signal (terminal) | Camera power supply circuits | ||
| Threshold | Camera power supply voltage is 5.9 V-6.5 V when ON, or 0 V when OFF | ||
| Diagnosis delay time | — | ||
POSSIBLE CAUSE
Camera power supply output circuit
Around view monitor control unit
Front camera
Rear camera
Side camera LH
Side camera RH
FAIL-SAFE
Camera power output is stopped.
PERFORM DTC CONFIRMATION PROCEDURE
CONSULT
Ignition switch ON.
Select “Self Diagnostic Result” mode of “AVM”.
Check DTC.
Is DTC U1302 detected?
YES>>Proceed to DTC Diagnosis Procedure.
NO>>To check malfunction symptom before repair: Intermittent Incident.
NO>>Confirmation after repair: Inspection End.
CHECK CAMERA DATA MONITOR
CONSULT
Check CAMERA IMAGE SIG for each camera in “Data Monitor” mode of “AVM”.
Is “OK” displayed for all cameras?
YES>>Refer to Intermittent Incident.
NO>>Front camera – GO TO 2.
NO>>Rear camera – GO TO 4.
NO>>LH side camera – GO TO 6.
NO>>RH side camera – GO TO 8.
CHECK FRONT CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
Ignition switch OFF.
Disconnect around view monitor control unit connector and front camera connector.
Check continuity between around view monitor control unit connector and front camera connector.
Around view monitor control unit Front camera Continuity Connector Terminal Connector Terminal M96 6 E226 2 Yes 5 1 Check continuity between around view monitor control unit connector and ground.
Around view monitor control unit Ground Continuity Connector Terminal M96 6 — No
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness or connectors.
CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE (FRONT CAMERA)
Connect around view monitor control unit connector and front camera connector.
Ignition switch ON.
Check voltage between around view monitor control unit connector terminals.
Around view monitor control unit M96 Condition Voltage
(Approx.)(+) (−) Terminal Terminal 6 5 CAMERA switch is ON or shift position is “D”. 6.2 V
Is the inspection result normal?
YES>>Replace front camera. Refer to Removal and Installation.
NO>>Replace around view monitor control unit. Refer to Removal and Installation.
CHECK REAR CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
Ignition switch OFF.
Disconnect around view monitor control unit connector and rear camera connector.
Check continuity between around view monitor control unit connector and rear camera connector.
Around view monitor control unit Rear camera Continuity Connector Terminal Connector Terminal M96 18 D564 2 Yes 17 1 Check continuity between around view monitor control unit connector and ground.
Around view monitor control unit Ground Continuity Connector Terminal M96 18 — No
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace harness or connectors.
CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE (REAR CAMERA)
Connect around view monitor control unit connector and rear camera connector.
Ignition switch ON.
Check voltage between around view monitor control unit connector terminals.
Around view monitor control unit M96 Condition Voltage
(Approx.)(+) (−) Terminal Terminal 18 17 CAMERA switch is ON or shift position is “R”. 6.2 V
Is the inspection result normal?
YES>>Replace rear camera. Refer to Removal and Installation.
NO>>Replace around view monitor control unit. Refer to Removal and Installation.
CHECK LH SIDE CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
Ignition switch OFF.
Disconnect around view monitor control unit connector and LH side camera connector.
Check continuity between around view monitor control unit connector and LH side camera connector.
Around view monitor control unit LH side camera Continuity Connector Terminal Connector Terminal M96 14 D4 10 Yes 13 11 Check continuity between around view monitor control unit connector and ground.
Around view monitor control unit Ground Continuity Connector Terminal M96 14 — No
Is the inspection result normal?
YES>>GO TO 7.
NO>>Repair or replace harness or connectors.
CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE (LH SIDE CAMERA)
Connect around view monitor control unit connector and LH side camera connector.
Ignition switch ON.
Check voltage between around view monitor control unit connector terminals.
Around view monitor control unit Condition Voltage
(Approx.)Connector (+) (−) Terminal Terminal M96 14 13 CAMERA switch is ON or shift position is “D” or “R”. 6.2 V
Is the inspection result normal?
YES>>Replace LH side camera. Refer to Removal and Installation.
NO>>Replace around view monitor control unit. Refer to Removal and Installation.
CHECK RH SIDE CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
Ignition switch OFF.
Disconnect around view monitor control unit connector and RH side camera connector.
Check continuity between around view monitor control unit connector and RH side camera connector.
Around view monitor control unit RH side camera Continuity Connector Terminal Connector Terminal M96 10 D107 10 Yes 9 11 Check continuity between around view monitor control unit connector and ground.
Around view monitor control unit Ground Continuity Connector Terminal M96 10 — No
Is the inspection result normal?
YES>>GO TO 9.
NO>>Repair or replace harness or connectors.
CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE (RH SIDE CAMERA)
Connect around view monitor control unit connector and RH side camera connector.
Ignition switch ON.
Check voltage between around view monitor control unit connector terminals.
Around view monitor control unit M96 Condition Voltage
(Approx.)(+) (−) Terminal Terminal 10 9 CAMERA switch is ON or shift position is “D” or “R”. 6.2 V
Is the inspection result normal?
YES>>Replace RH side camera. Refer to Removal and Installation.
NO>>Replace around view monitor control unit. Refer to Removal and Installation.