3zr-fae Battery / Charging

Removal

~2min read

REMOVAL

PRECAUTION / NOTICE / HINT

The procedures required (adjustment, calibration, initialization or registration) that must be performed after parts are removed, installed or replaced during Generator Assembly removal/installation are indicated below.

Procedure Required After Replacing / Removing / Installing Parts

Replacement part or procedure

Required Procedure

Effect/Inoperative function when procedure not performed

Link

Disconnect the cable from the negative (-) battery terminal.

Initialize Back Door Lock

Door Lock Control System

Memorize Steering Angle Neutral Point

Lane Departure Alert System (with Steering Control)

Pre-Collision System

PROCEDURE

1. PRECAUTIONS

NOTICE:

After turning the ignition switch OFF, a waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, be sure to read the precautions for disconnecting the cable from the negative (-) battery terminal before performing the work.

Click here

2. DISCONNECT THE CABLE FROM THE NEGATIVE BATTERY TERMINAL

Click here

NOTICE:

When the cable has been disconnected, some systems must be reset after the cable is reconnected.

Click here

3. REMOVE FAN AND GENERATOR V BELT

Click here

4. REMOVE GENERATOR ASSEMBLY

(a) Remove the Generator Terminal Cap Assembly.

(b) Remove the nut and disconnect the cable from terminal B.

(c) Disconnect the Generator Assembly connector.

(d) Release the clip to disconnect the wire harness from the wire harness clamp bracket.

(e) Remove the 2 bolts and the Generator Assembly.

(f) Remove the bolt and the wire harness clamp bracket from the Generator Assembly.