Heater / Air Conditioning

Front Blower Motor (Valeo Make)

~1min read

Removal

REMOVAL

PROCEDURE

1. REMOVE NO. 2 INSTRUMENT PANEL LOWER COVER SUB-ASSEMBLY

Click here

2. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

(a) Disconnect the connector.

(b) Remove the 3 screws and the blower motor and fan assembly.

NOTICE:

Replace the blower motor and fan assembly if it has been dropped or subjected to a severe impact.

Components

COMPONENTS

ILLUSTRATION

*1

BLOWER MOTOR SUB-ASSEMBLY WITH FAN

*2

NO. 2 INSTRUMENT PANEL LOWER COVER SUB-ASSEMBLY

Inspection

INSPECTION

PROCEDURE

1. INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

(a) Check operation.

(1) Apply battery voltage to the blower motor with fan sub-assembly and check that the motor operates.

Specified condition:

Measurement Condition

Specified Condition

Battery positive (+) → Terminal 2

Battery negative (-) → Terminal 1

The blower motor with fan sub-assembly operates properly.

If the result is not as specified, replace the blower motor with fan sub-assembly.

*a

Component without wire harness connected

(Blower Motor with Fan Sub-assembly)

Installation

INSTALLATION

PROCEDURE

1. INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY

(a) Install the blower motor and fan assembly using the 3 screws.

NOTICE:

Replace the blower motor and fan assembly if it has been dropped or subjected to a severe impact.

(b) Connect the connector.

2. INSTALL NO. 2 INSTRUMENT PANEL LOWER COVER SUB-ASSEMBLY

Click here